H05VVC4V5-K

Conductor: Soft finely stranded bare copper wires following VDE-0295 Cl 5, IEC 60228 Cl-5
Insulation: PVC T12, following DIN VDE 0281 part 1
Inner Jacket: PVC TM2 inner jacket, following DIN VDE 0281 part 1
Conductor: Soft finely stranded bare copper wires following VDE-0295 Cl 5, IEC 60228 Cl-5
Insulation: PVC T12, following DIN VDE 0281 part 1
Inner Jacket: PVC TM2 inner jacket, following DIN VDE 0281 part 1

    oops...!

    no product data.

    Go to homepage

    Material

    Conductor: Soft finely stranded bare copper wires following VDE-0295 Cl 5, IEC 60228 Cl-5

    Insulation: PVC T12, following DIN VDE 0281 part 1

    Inner Jacket: PVC TM2 inner jacket, following DIN VDE 0281 part 1

    Shield: Tinned copper braid shielding,coverage more than 80%

    Outer jacket: PVC

    Outer jacket color: Black(RAL9005)

    Standards: HD 21.13 S1, VDE-0281 P-13, CEI 20-20/13, CEI 20-35 (EN60332-1), CEI 20-52


    Features

    Comply with EU coordination standards

    Ultrafine conductor, soft, small bending Angle

    Can able to bear external mechanical forces and abrasion resistance

    H05VVC4V5-K Cords

    H05VVC4V5-K Cords


    H05VVC4V5-K Power Cords

    H05VVC4V5-K Power Cords


    H05VVC4V5-K Cable

    H05VVC4V5-K Cable


    Technical Parameters

    Rated voltage: 300V/500V

    Test voltage: 2000V

    Minimum bending radius: Fixed installation: 5×D  D=outer cable diameter

    Movable installation: 10×D

    Operating temperature: Fixed installation: -40 - +70℃

    Movable installation: -5 - +70℃

    Flame resistance: Flame resistance and self-extinguishing according to IEC60332-1

    Insulation resistance: 20 MΩ/km


    Parameter

    Part No.

    Cores

    Conductor

    Insulation

    Out Jacket

    Conductor Resistance at 20℃ MAX

    Weight

    kg/km

    Section

    mm2

    Thickness

    mm

    Dia

    mm

    Thickness

    mm

    Dia

    mm

    Bare

    Ω/km

    Tinned

    Ω/km

    H05VVC4V5-K

    2

    0.50

    0.6

    2.1

    0.9

    7.7

    39.0

    40.1

    104.8

    H05VVC4V5-K

    3

    0.50

    0.6

    2.1

    0.9

    8.0

    39.0

    40.1

    114.6

    H05VVC4V5-K

    4

    0.5

    0.6

    2.1

    0.9

    8.5

    39.0

    40.1

    81.8

    H05VVC4V5-K

    5

    0.5

    0.6

    2.1

    1.0

    9.3

    39.0

    40.1

    124.6

    H05VVC4V5-K

    7

    0.75

    0.6

    2.1

    1.1

    10.8

    39.0

    40.1

    154.3

    H05VVC4V5-K

    2

    0.75

    0.6

    2.3

    0.9

    8.0

    24.5

    24.8

    204.2

    H05VVC4V5-K

    3

    0.75

    0.6

    2.3

    0.9

    8.3

    24.5

    24.8

    114.7

    H05VVC4V5-K

    4

    0.75

    0.6

    2.3

    1.0

    9.1

    24.5

    24.8

    124.2

    H05VVC4V5-K

    5

    0.75

    0.6

    2.3

    1.1

    9.7

    24.5

    24.8

    153.8

    H05VVC4V5-K

    7

    0.75

    0.6

    2.3

    1.2

    11.5

    24.5

    24.8

    176.2

    H05VVC4V5-K

    2

    1.0

    0.6

    2.5

    0.9

    8.2

    18.1

    18.2

    251.4

    H05VVC4V5-K

    3

    1.0

    0.6

    2.5

    1.00

    8.8

    18.1

    18.2

    126.5

    H05VVC4V5-K

    4

    1.0

    0.6

    2.5

    1.0

    9.4

    18.1

    18.2

    145.6

    H05VVC4V5-K

    5

    1.0

    0.6

    2.5

    1.1

    10.3

    18.1

    18.2

    170.2

    H05VVC4V5-K

    7

    1.0

    0.6

    2.5

    1.2

    12.2

    18.1

    18.2

    200.4

    H05VVC4V5-K

    2

    2.5

    0.8

    3.2

    1.1

    10.7

    7.14

    7.56

    215.3

    H05VVC4V5-K

    3

    2.5

    0.8

    3.2

    1.1

    11.3

    7.14

    7.56

    250.1

    H05VVC4V5-K

    4

    2.5

    0.8

    3.2

    1.2

    12.6

    7.14

    7.56

    305.3

    H05VVC4V5-K

    5

    2.5

    0.8

    3.2

    1.3

    13.9

    7.14

    7.56

    385.2

    H05VVC4V5-K

    7

    2.5

    0.8

    3.2

    1.5

    16.5

    7.14

    7.56

    525.1


    Application

    Suitable for dry, wet environment, but cannot be used in the outdoors. They are used for shielding terminals and connection cables In control, measurement and signal technology. Copper wire braided shield outside interference, such as electromagnetic field and the spurious frequency.

    Used as signal and pulse cables in the industrial plants, machinery and process control and inspection systems.


    contact us
    Feel free to contact us

    We are more than happy to manufacture top-of-the-line products for your project. Take a look around our website. If you have a query or you need advice, just contact us. We'll take time to help you.

    Related Products
    no data
    Shanghai Fengy Cable Technology Co., Ltd. always adheres to the business philosophy of "customer first, quality foremost," We continually enhance our company's strengths to provide better products and prices to our clients, fostering mutual growth, We look forward to collaborating with you to achieve a brilliant future together.
    Contact with us
    Contacts: Salina Zhang
    Phone: +86-21-54716991
    WhatsApp: +86 18917744190
    Add: No.2 building , No. 951 Jianchuan Road, Shanghai, China
    Customer service